Sodium Ion Batteries

Introduction

What are Sodium Ion Batteries?

Benan Intelligent Sodium-Ion Battery System is a smart sodium-ion battery energy storage solution launched for UPS. It features advantages including safety and reliability, long service life, small footprint, and easy operation and maintenance. Adopting the industry-unique sodium-ion battery technology, it achieves ” intrinsic safety” in design and completely avoids thermal runaway.

Smart Control & Monitoring

Remote diagnosis and updates via the inverter, with automatic reboot after undervoltage.

Superb Safety & Reliability

Reliable sodium-ion technology with high cycle stability and IP56 protection for safe outdoor installation.

Friendly & Thoughtful Design

Stackable auto-recognition modules with Plug & Play wiring for fast and easy installation.

Flexible Applications

Flexible capacity and stackable modules

Single Cell

Configuration
Single cell
Rated Capacity
52Ah @6C, 2.25~3.25V

58Ah @0.5C, 1.5~3.25V
Charging Rate
≤1C, default 0.5C
Max. Continuous Discharge Rate
6C
Rated Voltage
2.85Vdc
Voltage Range
2.25~3.4Vdc
Dimensions (W×D×H)
50×160×116 mm
Weight
1.7kg

Module

Configuration
2P18S
Rated Capacity
52Ah @6C, 40.5~58.4V

58Ah @0.5C, 27~61.2V
Charging Rate
≤1C, default 0.5C
Max. Continuous Discharge Rate
6C
Rated Voltage
51.3Vdc
Voltage Range
≤2°C
Dimensions (W×D×H)
500×835×150 mm
Weight
65kg

Battery Energy Storage System

Product Model
Product Model
Cell Material
NFPP
Charging Current
≤1C, default 0.5C
Max. Continuous Discharge Rate
6C
Rated Voltage
512V
Typical Voltage Range
405V~584V
Cycle Life
20000 cycles @50%DOD
Configuration
2P180S
Nominal Capacity
104Ah / 53.3kWh, 405V~584V and 116Ah / 59.5kWh, 270V~584V
Weight
1100kg
Dimensions (W×D×H)
600×1000×2200 mm
Self-Discharge Rate
≤5% (0-30°C / 3 months)
Communication Interface
FE, RS485, Dry contact, SNMP
Protection Functions
Over-temperature, over-current, short-circuit, over-charge, over-discharge, etc.
Certifications
UN38.3, UL1973, UL9540A, IEC62619, IEC62040, IEC61000, IEC62477
Discharge Capability
300kVA@10min
Storage Temperature
-40°C ~ 60°C
Operating Temperature
-40°C ~ 60°C (10-35°C is recommended)
Relative Humidity
5% ~ 95% (no condensation)
Altitude
0 ~ 4000m; derating should be considered for altitudesover 2000m

Performance Curves at Different C-Rates (25°C)

Charging & Discharging Curves

Cell voltage response across the full range of charge and discharge rates, measured at 25°C.

Charging Curves Under Different Charging Rate@25℃

Voltage (V) vs Charge Time (MIN)

Charging Curves Under Different Charging Rate@25℃

Voltage (V) vs Charge Time (MIN)

Performance Curves at Different C-Rates (25°C)

Charging & Discharging Curves